Missing chunk number 0
2 posters
Page 1 of 1
Missing chunk number 0
Version: 10.22
CP: 18.00.74
CUP: 1.260
Probe active but not processing anything. "Missing chunk number 0" keeps showing up in the log.
Thanks in advance
Louis
CP: 18.00.74
CUP: 1.260
Probe active but not processing anything. "Missing chunk number 0" keeps showing up in the log.
Thanks in advance
Louis
Sopkat- Posts : 3
Join date : 2017-01-18
Re: Missing chunk number 0
Hi Louis
Sounds like Probe Database is corrupt. Try the following:
1. Stop the probe service only(not the Probe DB service)
2. Run the CleanProbeData.bat file located at (C):\hp\UCMDB\DataFlowProbe\tools\. (You may have to right click on the file and select Run as administrator). This may take a while to complete.
3. Restart the probe service
Hope this helps
Admin
Sounds like Probe Database is corrupt. Try the following:
1. Stop the probe service only(not the Probe DB service)
2. Run the CleanProbeData.bat file located at (C):\hp\UCMDB\DataFlowProbe\tools\. (You may have to right click on the file and select Run as administrator). This may take a while to complete.
3. Restart the probe service
Hope this helps
Admin